    PYQs/2018/Q105
    Verified answer (AI cross-checked + SME reviewed)

    Q105 (2018, Anesthesia Circuits) — Correct answer: C. Mapleson A.

    NEET PG 2018
    Q105
    syringe Anesthesia
    Anesthesia Circuits
    tier-2 (3/3 verifier agreement)

    What is the most effective circuit for anesthesia under spontaneous breathing?

    A. Mapleson C
    B. Mapleson B
    C. Mapleson A
    D. Mapleson D

    Correct Answer: C. Mapleson A

    Mapleson A (also called the Magill circuit) is the gold standard for spontaneous breathing anesthesia because it offers the lowest fresh gas flow (FGF) requirement while maintaining efficient elimination of carbon dioxide. In this circuit, the breathing bag and expiratory valve are positioned at the patient end, allowing exhaled gases to exit through the expiratory valve before reaching the reservoir bag. During inspiration, the patient draws fresh gas directly from the circuit, and during expiration, the first portion of exhaled gas (dead space gas) exits through the open expiratory valve, while alveolar gas fills the reservoir bag. This arrangement ensures minimal rebreathing of CO₂ while requiring only 0.5–1 times the minute ventilation as FGF—the most economical among all Mapleson circuits. In Indian operating theaters where gas conservation is critical due to cost considerations, Mapleson A remains the preferred choice for spontaneous breathing procedures. The circuit's efficiency is particularly valuable in prolonged surgeries and resource-limited settings. Its main limitation is that it becomes inefficient during controlled ventilation, making it unsuitable for paralyzed patients.

    Why the other options are wrong

    A. Mapleson C — Mapleson C (T-piece circuit) requires 2–3 times minute ventilation as FGF for adequate CO₂ elimination during spontaneous breathing, making it highly inefficient. While useful in pediatric anesthesia due to its simplicity and low resistance, it is wasteful of anesthetic gases. This circuit is designed for short procedures in children, not for economical spontaneous breathing in adults. B. Mapleson B — Mapleson B (Lack circuit) requires 1.5–2 times minute ventilation as FGF during spontaneous breathing, which is significantly higher than Mapleson A. Although it has a compact design and is sometimes used in dental anesthesia, its poor gas efficiency makes it unsuitable as the most effective circuit for routine spontaneous breathing anesthesia in operating theaters. D. Mapleson D — Mapleson D (Bain circuit) requires 2–3 times minute ventilation as FGF during spontaneous breathing, making it very inefficient for this mode. Although Mapleson D becomes the most efficient circuit during controlled ventilation (requiring only 0.5 times minute ventilation as FGF), it is unsuitable for spontaneous breathing. This is a classic NBE trap—confusing its efficiency in controlled ventilation with spontaneous breathing.

    High-Yield Facts

    • Mapleson A requires 0.5–1 × minute ventilation as FGF during spontaneous breathing—the lowest among all Mapleson circuits.
    • Mapleson D is most efficient during controlled ventilation (0.5 × minute ventilation), not spontaneous breathing—inverse efficiency pattern.
    • Mapleson A has expiratory valve at patient end, allowing dead space gas to exit before reaching the reservoir bag.
    • Mapleson C and B require 2–3 and 1.5–2 × minute ventilation as FGF respectively—both wasteful during spontaneous breathing.
    • Magill circuit (Mapleson A) is preferred in Indian ORs for cost-effective anesthesia in prolonged spontaneous breathing procedures.

    Mnemonics

    Mapleson Efficiency in Spontaneous Breathing A < B < C (in terms of FGF requirement). Mapleson A is most efficient (0.5–1×), B is intermediate (1.5–2×), C is least efficient (2–3×). Remember: A is 'Awesome' for spontaneous breathing. Mapleson D Trap D is Different—it's most efficient during controlled ventilation (0.5×), NOT spontaneous breathing (2–3×). Inverse pattern compared to A, B, C. Use this to avoid the NBE trap.

    NBE Trap

    NBE commonly pairs Mapleson D with "most efficient circuit" to trap students who remember only that Mapleson D is efficient during controlled ventilation, forgetting that the question specifies spontaneous breathing—where Mapleson A reigns supreme.

    Clinical Pearl

    In Indian government hospitals and resource-limited settings, Mapleson A (Magill circuit) is the workhorse for spontaneous breathing anesthesia because it minimizes wasted anesthetic gas—a critical cost consideration. A 2-hour spontaneous breathing surgery with Mapleson A uses significantly less sevoflurane or isoflurane compared to Mapleson C or D, directly impacting departmental budgets.

    _Reference: Guyton & Hall Textbook of Medical Physiology (Respiratory Physiology chapter on anesthesia circuits); Bailey & Love's Short Practice of Surgery (Anesthesia chapter)_

    Ask AI Tutor about this question

    Stuck on a distractor? Want a worked-through clinical scenario? The AI Tutor is a NEETPGAI Pro feature — sign up free to practice the full question bank, then unlock the AI Tutor when you're ready.

    Explain this concept in plain language
    Why is each wrong option wrong?
    Give me a clinical scenario where this is tested
    Sign up free Already have an account? Log in

    Free to start, no credit card required. The 3 prompts/day quota is shared with practice + tutor + deep-dive across NEETPGAI.

    Memory-based reconstruction

    NBE does not officially release NEET PG papers per the 2025 Supreme Court directive. This question was reconstructed from 1 community source: PrepLadder NEET PG 2018 Recall PDF. Cross-verified by Claude Haiku 4.5 + Gemini 2.5 Flash + community-aggregate vote, then reviewed by a practising medical SME.

    ← All NEET PG 2018 questionsPractice with AI Tutor →

    Join our NEET PG community

    Daily MCQs, study tips, and topper strategies on Telegram.

    Join on Telegram →